Why This System Size
Solar array sizing
Using an estimated daily demand of 5,000 Wh, 4.5 peak sun hours, and a 78% system efficiency assumption, the estimated solar array need is approximately 1,425 W.
Battery sizing
With 5,000 Wh of daily use and an assumed 85% usable battery fraction per cycle, the estimated storage need is approximately 5,883 Wh. This accounts for not fully depleting the battery bank on a typical day.
Inverter sizing
Based on an estimated peak AC load of 2,400 W and a 1.30× surge margin, the estimated inverter need is approximately 3,120 W. This provides headroom for brief startup loads above continuous draw.
System Challenge
Limited roof real estate requiring high-voltage residential panel strings
Limited roof area may require higher-efficiency panels or alternative mounting strategies. Planning should balance available roof space against the calculated daily energy target.